Compare commits
2 Commits
40bbf1ca65
...
d003fd5f0f
| Author | SHA1 | Date | |
|---|---|---|---|
| d003fd5f0f | |||
| 62611ecc37 |
@@ -1 +1 @@
|
||||
{"pid": 67, "version": 1, "ha_version": "2025.10.4", "start_ts": 1762379484.0212016}
|
||||
{"pid": 68, "version": 1, "ha_version": "2025.10.4", "start_ts": 1764005948.2089655}
|
||||
@@ -296,3 +296,38 @@
|
||||
target:
|
||||
entity_id: light.luce_salotto
|
||||
mode: single
|
||||
- id: '1763497184744'
|
||||
alias: ETcontroller_pub_setFixHPlimit
|
||||
description: ''
|
||||
triggers:
|
||||
- trigger: state
|
||||
entity_id:
|
||||
- input_select.fix_hp_power
|
||||
conditions: []
|
||||
actions:
|
||||
- action: mqtt.publish
|
||||
metadata: {}
|
||||
data_template:
|
||||
topic: etcontroller/sw/commands
|
||||
payload: "{\"cmd\": \"setFixHPlimit\", \"params\": {\n \"level\": \"{{states('input_select.fix_hp_power')}}\",\n
|
||||
\ \"duration\": {{states('input_number.fix_hp_power_duration')}} }}"
|
||||
mode: single
|
||||
- id: '1764007463105'
|
||||
alias: ETcontroller_fix_limit_copy
|
||||
description: 'This Automation allows to copy status from MQTT read HP Fix Limit
|
||||
set by ETcontroller.py to internal input_select.fix_hp_power in order to align.
|
||||
dashboards when fix_hp_limit expires
|
||||
|
||||
'
|
||||
triggers:
|
||||
- trigger: state
|
||||
entity_id:
|
||||
- sensor.fix_hp_level_read
|
||||
conditions: []
|
||||
actions:
|
||||
- action: input_select.select_option
|
||||
target:
|
||||
entity_id: input_select.fix_hp_power
|
||||
data_template:
|
||||
option: '{{ states(''sensor.fix_hp_level_read'') }}'
|
||||
mode: single
|
||||
|
||||
@@ -21,7 +21,7 @@ triggers:
|
||||
id: p1-confort-light-dim
|
||||
- trigger: sun
|
||||
event: sunset
|
||||
offset: 00:30:00
|
||||
offset: 00:15:00
|
||||
id: p1-confort-light-on
|
||||
- trigger: state
|
||||
entity_id:
|
||||
|
||||
@@ -3,7 +3,7 @@ default_config:
|
||||
|
||||
# packages directory
|
||||
homeassistant:
|
||||
packages: !include_dir_named packages
|
||||
packages: !include_dir_named packages_dir
|
||||
|
||||
# Load frontend themes from the themes folder
|
||||
frontend:
|
||||
@@ -21,6 +21,7 @@ light: !include lights.yaml
|
||||
climate: !include climates.yaml
|
||||
binary_sensor: !include binary_sensors.yaml
|
||||
template: !include templates.yaml
|
||||
mqtt: !include mqtt.yaml
|
||||
|
||||
# DO NOT remove - Sets MariaDB as database
|
||||
recorder:
|
||||
@@ -47,95 +48,6 @@ logbook:
|
||||
- sensor.date_time_iso
|
||||
- sensor.date_time_utc
|
||||
|
||||
# Zigbee Network Map not Working
|
||||
# mqtt:
|
||||
# sensor:
|
||||
# - name: Zigbee2mqtt Networkmap
|
||||
# # if you change base_topic of Zigbee2mqtt, change state_topic accordingly
|
||||
# state_topic: zigbee2mqtt/bridge/response/networkmap
|
||||
# value_template: >-
|
||||
# {{ now().strftime('%Y-%m-%d %H:%M:%S') }}
|
||||
# # again, if you change base_topic of Zigbee2mqtt, change json_attributes_topic accordingly
|
||||
# json_attributes_topic: zigbee2mqtt/bridge/response/networkmap
|
||||
# json_attributes_template: "{{ value_json.data.value | tojson }}"
|
||||
mqtt:
|
||||
- sensor:
|
||||
- name: HP_power
|
||||
unit_of_measurement: "W"
|
||||
unique_id: mon_hp_pw
|
||||
state_topic: monitoring/hw/heatpump
|
||||
value_template: >-
|
||||
{{ value_json.power | int }}
|
||||
- name: HP_max_power
|
||||
unit_of_measurement: "W"
|
||||
unique_id: mon_hp_max_pw
|
||||
state_topic: monitoring/hw/heatpump
|
||||
value_template: >-
|
||||
{{ value_json.hp_max_power | int }}
|
||||
- name: ACS_temp
|
||||
unit_of_measurement: "'C"
|
||||
unique_id: mon_acs_temp
|
||||
state_topic: monitoring/hw/temperatures
|
||||
value_template: >-
|
||||
{{ value_json.acs | int }}
|
||||
- name: Heating_temp
|
||||
unit_of_measurement: "'C"
|
||||
unique_id: mon_heating_temp
|
||||
state_topic: monitoring/hw/temperatures
|
||||
value_template: >-
|
||||
{{ value_json.heating | int }}
|
||||
- name: Solar_temp
|
||||
unit_of_measurement: "'C"
|
||||
unique_id: mon_solar_temp
|
||||
state_topic: monitoring/hw/temperatures
|
||||
value_template: >-
|
||||
{{ value_json.solar | int }}
|
||||
- name: SE_AC_voltage
|
||||
unit_of_measurement: "V"
|
||||
unique_id: mon_se_ac_voltage
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.ac_v | int) / 100 }}
|
||||
- name: SE_AC_current
|
||||
unit_of_measurement: "A"
|
||||
unique_id: mon_se_ac_current
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.ac_i | int) / 100 }}
|
||||
- name: SE_DC_voltage
|
||||
unit_of_measurement: "V"
|
||||
unique_id: mon_se_dc_voltage
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.dc_v | int) / 100 }}
|
||||
- name: SE_DC_current
|
||||
unit_of_measurement: "A"
|
||||
unique_id: mon_se_dc_current
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.dc_i | int) / 100 }}
|
||||
- name: SE_Heatsink_temp
|
||||
unit_of_measurement: "'C"
|
||||
unique_id: mon_se_ht_temperature
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.hs_t | int) / 100 }}
|
||||
- name: SE_Total_power
|
||||
unit_of_measurement: "MW"
|
||||
unique_id: mon_se_tot_p
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.w_tot | int) / 1000000 }}
|
||||
- name: Zigbee2mqtt Networkmap
|
||||
unique_id: zigbee2mqtt_bridge_network_map
|
||||
# if you change base_topic of Zigbee2mqtt, change state_topic accordingly
|
||||
state_topic: zigbee2mqtt/bridge/response/networkmap
|
||||
value_template: >-
|
||||
{{ now().strftime('%Y-%m-%d %H:%M:%S') }}
|
||||
# again, if you change base_topic of Zigbee2mqtt, change json_attributes_topic accordingly
|
||||
json_attributes_topic: zigbee2mqtt/bridge/response/networkmap
|
||||
json_attributes_template: "{{ value_json.data.value | tojson }}"
|
||||
|
||||
# add additional cards
|
||||
lovelace:
|
||||
mode: yaml
|
||||
|
||||
82
mqtt.yaml
Normal file
82
mqtt.yaml
Normal file
@@ -0,0 +1,82 @@
|
||||
---
|
||||
- sensor:
|
||||
- name: HP_power
|
||||
unit_of_measurement: "W"
|
||||
unique_id: mon_hp_pw
|
||||
state_topic: monitoring/hw/heatpump
|
||||
value_template: >-
|
||||
{{ value_json.power | int }}
|
||||
- name: HP_max_power
|
||||
unit_of_measurement: "W"
|
||||
unique_id: mon_hp_max_pw
|
||||
state_topic: monitoring/hw/heatpump
|
||||
value_template: >-
|
||||
{{ value_json.hp_max_power | int }}
|
||||
- name: ACS_temp
|
||||
unit_of_measurement: "'C"
|
||||
unique_id: mon_acs_temp
|
||||
state_topic: monitoring/hw/temperatures
|
||||
value_template: >-
|
||||
{{ value_json.acs | int }}
|
||||
- name: Heating_temp
|
||||
unit_of_measurement: "'C"
|
||||
unique_id: mon_heating_temp
|
||||
state_topic: monitoring/hw/temperatures
|
||||
value_template: >-
|
||||
{{ value_json.heating | int }}
|
||||
- name: Solar_temp
|
||||
unit_of_measurement: "'C"
|
||||
unique_id: mon_solar_temp
|
||||
state_topic: monitoring/hw/temperatures
|
||||
value_template: >-
|
||||
{{ value_json.solar | int }}
|
||||
- name: SE_AC_voltage
|
||||
unit_of_measurement: "V"
|
||||
unique_id: mon_se_ac_voltage
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.ac_v | int) / 100 }}
|
||||
- name: SE_AC_current
|
||||
unit_of_measurement: "A"
|
||||
unique_id: mon_se_ac_current
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.ac_i | int) / 100 }}
|
||||
- name: SE_DC_voltage
|
||||
unit_of_measurement: "V"
|
||||
unique_id: mon_se_dc_voltage
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.dc_v | int) / 100 }}
|
||||
- name: SE_DC_current
|
||||
unit_of_measurement: "A"
|
||||
unique_id: mon_se_dc_current
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.dc_i | int) / 100 }}
|
||||
- name: SE_Heatsink_temp
|
||||
unit_of_measurement: "'C"
|
||||
unique_id: mon_se_ht_temperature
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.hs_t | int) / 100 }}
|
||||
- name: SE_Total_power
|
||||
unit_of_measurement: "MW"
|
||||
unique_id: mon_se_tot_p
|
||||
state_topic: monitoring/se/values
|
||||
value_template: >-
|
||||
{{ (value_json.w_tot | int) / 1000000 }}
|
||||
- name: fix_hp_level_read
|
||||
unique_id: fix_hp_level_read
|
||||
state_topic: etcontroller/sw/answers
|
||||
value_template: >-
|
||||
{{ value_json['values'].level }}
|
||||
- name: Zigbee2mqtt Networkmap
|
||||
unique_id: zigbee2mqtt_bridge_network_map
|
||||
# if you change base_topic of Zigbee2mqtt, change state_topic accordingly
|
||||
state_topic: zigbee2mqtt/bridge/response/networkmap
|
||||
value_template: >-
|
||||
{{ now().strftime('%Y-%m-%d %H:%M:%S') }}
|
||||
# again, if you change base_topic of Zigbee2mqtt, change json_attributes_topic accordingly
|
||||
json_attributes_topic: zigbee2mqtt/bridge/response/networkmap
|
||||
json_attributes_template: "{{ value_json.data.value | tojson }}"
|
||||
Reference in New Issue
Block a user