Files
home-assistant/blueprints/automation/homeassistant/auto_ac_control.yaml
T

177 lines
5.7 KiB
YAML

blueprint:
name: Auto AC Control
description: Auto Turn on Air Conditioning
domain: automation
author: Tiziano Trabattoni
input:
temp_threshold:
name: Temperature Threshold to switch AC on
description: This threshold is the temperature above which AC must be switched on
default: 29.0
selector:
number:
min: 25.0
max: 40.0
step: 0.5
unit_of_measurement: celsius
temp_hist:
name: Temperature Histeresys from off to on
description: This gap is difference between on and off
default: 2.0
selector:
number:
min: 1.0
max: 4.0
step: 0.5
unit_of_measurement: celsius
climate_target:
name: Termostat Control
description: Identifies the AC climate to be controlled
selector:
entity:
filter:
- domain: climate
fan_ctrl:
name: Auto AC controls fan speed
description: Allow Auto AC to set fan speed accordingly to difference between actual and target temperature
default: false
selector:
boolean: {}
override_duration:
name: Manual Override Duration
description: Hours to pause automatic control if a manual change is detected
default: 1
selector:
number:
min: 0.1
max: 4
step: 0.1
unit_of_measurement: hours
mode: restart
trace:
stored_traces: 30
variables:
target_AC: !input climate_target
target_temp: !input temp_threshold
target_hist: !input temp_hist
fan_control: !input fan_ctrl
override_hours: !input override_duration
triggers:
# Trigger when the room temperature changes
- trigger: state
entity_id: !input climate_target
attribute: current_temperature
id: temp_change
# # Trigger instantly when someone manually changes the AC mode
# - trigger: state
# entity_id: !input climate_target
# id: state_change
conditions:
# 1. Verifica di sicurezza sullo stato dell'entità
- condition: template
value_template: "{{ trigger.to_state is not none }}"
# # 2. Se l'automazione sta già eseguendo il "delay" di override, ignora i cambi di temperatura
# - condition: template
# value_template: >-
# {{ not (this.attributes.current == 1 and trigger.id == 'temp_change') }}
actions:
- choose:
# DETECT MANUAL OVERRIDE: Triggered by state change, but context shows it was NOT the automation itself
# - conditions:
# - condition: template
# value_template: "{{ trigger.id == 'state_change' and trigger.to_state.context.id != context.id }}"
# sequence:
# - delay:
# hours: "{{ override_hours | int(2) }}"
# CONDITION 1: Turn AC ON & Adjust Fan
- conditions:
- condition: template
value_template: "{{ state_attr(target_AC, 'current_temperature') | float(0) >= target_temp }}"
- condition: or
conditions:
- condition: state
entity_id: !input climate_target
state: "off"
- condition: state
entity_id: !input climate_target
state: "heat_cool"
- condition: state
entity_id: !input climate_target
state: "dry"
- condition: state
entity_id: !input climate_target
state: "fan_only"
sequence:
- action: climate.set_hvac_mode
target:
entity_id: !input climate_target
data:
hvac_mode: cool
- action: climate.set_swing_mode
target:
entity_id: !input climate_target
data:
swing_mode: Horizontal
- if:
- condition: template
value_template: "{{ fan_control }}"
then:
- action: climate.set_fan_mode
target:
entity_id: !input climate_target
data:
fan_mode: >-
{% set curr_temp = state_attr(target_AC, 'current_temperature') | float(0) -%}
{% set targ_temp = state_attr(target_AC, 'temperature') | float(0) -%}
{% set diff_temp = curr_temp - targ_temp -%}
{% if diff_temp >= 4.0 -%}
5
{% elif diff_temp >= 3.5 and diff_temp < 4.0 -%}
4
{% elif diff_temp >= 3.0 and diff_temp < 3.5 -%}
3
{% elif diff_temp >= 1.5 and diff_temp < 3.0 -%}
2
{% else -%}
Auto
{% endif %}
else:
- action: climate.set_fan_mode
target:
entity_id: !input climate_target
data:
fan_mode: Auto
# CONDITION 2: Turn AC OFF (Hysteresis)
- conditions:
- condition: template
value_template: >-
{{ state_attr(target_AC, 'current_temperature') | float(0) <= (target_temp | float(0) - target_hist | float(0)) }}
- condition: state
entity_id: !input climate_target
state: "cool"
sequence:
- action: climate.set_swing_mode
target:
entity_id: !input climate_target
data:
swing_mode: Horizontal
- action: climate.set_fan_mode
target:
entity_id: !input climate_target
data:
fan_mode: Auto
- action: climate.turn_off
target:
entity_id: !input climate_target