Fine tune of home_only_power with rounding and AC power consumption
This commit is contained in:
+1
-1
@@ -44,7 +44,7 @@
|
||||
unit_of_measurement: kW
|
||||
default_entity_id: sensor.home_only_power
|
||||
name: Home Power without HP Pump and EVcharge
|
||||
state: "{{ (states('sensor.pw_load_power') | float) - (states('sensor.evcharge_total_power') | float) - ((states('sensor.hp_power') | float ) / 1000) }}"
|
||||
state: "{{ max(0, (states('sensor.pw_load_power') | float ) - (states('sensor.evcharge_total_power') | float) - ((states('sensor.hp_power') | float ) / 1000) - (((states('sensor.ac_power_monitoring_power_ab') | float ) / 1000) ) | round(3, 'half')) }}"
|
||||
|
||||
- sensor:
|
||||
- unique_id: ev_heat_power
|
||||
|
||||
Reference in New Issue